30A Electric Brewery Control Panel power cord (DIY Kit)

PWRCRD-DIY


30A power cord for powering our 30A control panels. It plugs into a standard 4-slot North American dryer wall receptacle (240V/30A NEMA 14-30R with ground). DIY Kit (4 wires must be attached between the cord and plug using a screwdriver). 

A locking female connector is used on the control panel side for added safety.

10 feet in length. Contact us for custom lengths.



What kind of wall outlet do I need to tell my electrician to install?

The 30A control panel power cord plugs into a standard North American dryer receptacle (4-prong 30A/240V). Ask your electrician to install a NEMA 14-30R receptacle. In the electrical breaker panel, the circuit breaker must be a 30A / 240V 2-pole breaker. We recommend that the breaker include GFCI protection.

 

Is a ground fault circuit interrupter (GFCI) included?

No. A GFCI must be used and may be installed in one of two places: Either in the circuit breaker in your home's electrical panel, or in-line with the control panel power cord.

We recommend that you check that whatever GFCI you intend on using adheres to your local electrical code in terms of trip settings and speed of operation. A GFCI is an absolute requirement for safe brewing. Do not confuse a GFCI with a circuit breaker: A circuit breaker saves equipment, a GFCI saves lives.

For more information see our section on control panel supply power.

 

Visit our official Control Panel Power Cord product thread in our forum.



Related Items